- Rich Electric Ei-8001 User Manual Download
- Rich Electric Ei-8001 User Manual Free
- Rich Electric Ei-8001 User Manual 2016
- Rich Electric Ei-8001 User Manual Youtube
EI-8001-User-Manual信息与通信工程科技专业资料 2950. Thank you for choosing Rich Electric -51. Nov 08, 2018 Your boy uncle Rich went to SEMA and saw the magestic Tesla powered old school mercury, how cool is it? Cadillac wiring manual 1981 free download. Well I find out just that from Stealth EV.
220V Class (3-Phase Input) 0.75kW~75kW
440V Class (3-Phase Input) 0.75kW~900kW
440V Class (3-Phase Input) 0.75kW~900kW
AC Inverter Motor Drive is the comprehensive flux vector control AC inverter. AC Inverter Motor Drive can be used in elevator, lift application. There are four control patterns: Standard V/F control, V/F control with PG feedback, Sensorless flux vector control and vector control with PG feedback. EI-Super provides the servo-like precision machinery to multiple types of motor drives. The capacity of AC Inverter Motor Drive is up to 900kW. Large power can be custom-designed in the cabinet protection.
Smooth operation, precise control and powerful functionality.
AC Inverter Motor Drive is a general-purpose inverter with flux vector control. It directly controls the current or torque in an AC induction motor. AC Inverter Motor Drive is suitable for a wide variety of applications.
AC Inverter Motor Drive provides smooth start-up at low speeds (1% of rated speed) and precise operation. Its auto-tuning function enables high performance tuning of all induction motors
AC Inverter Motor Drive provides smooth start-up at low speeds (1% of rated speed) and precise operation. Its auto-tuning function enables high performance tuning of all induction motors
AC inverter motor drive combines four control methods
open loop vector
flux vector
V/F control with PG feedback
V/F control
flux vector
V/F control with PG feedback
V/F control
From precision machinery to multiple motor drives, El Super N proves to be the ultimate drive for all applications. Features
32bit DSP microprocessor configuration
‧ magnetic field oriented flux vector contro
‧ auto-tune ability
‧ available for speed-type servo controller while PG feedback added
‧ RS-232/RS-485 serial communication port
‧ RS232/TCP-IP interface card
‧ capacities from 1HP – 400 HP
‧ optional DC reactor available (for reducing harmonic interference from the power supply)
‧ multi-language large screen LCD displays the drive status in six languages and a parameter copy mode function.
‧ magnetic field oriented flux vector contro
‧ auto-tune ability
‧ available for speed-type servo controller while PG feedback added
‧ RS-232/RS-485 serial communication port
‧ RS232/TCP-IP interface card
‧ capacities from 1HP – 400 HP
‧ optional DC reactor available (for reducing harmonic interference from the power supply)
‧ multi-language large screen LCD displays the drive status in six languages and a parameter copy mode function.
‧ English
‧ Chinese
‧ Russian
‧ German
‧ French
‧ Spanish
‧ Chinese
‧ Russian
‧ German
‧ French
‧ Spanish
Any type of machine starts smoothly at slow speeds.
EI-Super N features full-scale flux vector current control that directly controls motor torque based on present control theory utilising a magnetic flux observer and neuro-control. Ge over the range microwave user manual.
Rich Electric Ei-8001 User Manual Download
It features full torque control even at zero speed when PG option is added.
Precise control over a wide speed range.
EI-Super N features highly precise operation throughout the motor’s entire speed range, even under fluctuating load conditions.
Four controls in one device; the ultimate device for all applications.
![Rich Electric Ei-8001 User Manual Rich Electric Ei-8001 User Manual](/uploads/1/2/6/5/126529800/825041586.jpg)
Four control methods are included:
‧ Standard V/F control
‧ V/F control with PG feedback
‧ Sensorless flux vector control
‧ Flux vector current control with PG feedback
‧ Standard V/F control
‧ V/F control with PG feedback
‧ Sensorless flux vector control
‧ Flux vector current control with PG feedback
Simply select the parameters, EI-Super N can be applied to a wide range of applications from servo-like precision machinery to multiple motor drives.
Rich Electric Ei-8001 User Manual Free
Factory presets default to sensorless vector control type, but it can be configured to the V/F control mode for applications requiring multiple motors on one device, or set to flux vector current control mode (with PG) for hughly precise vector operation. (PG-B interface card is optional)
Rich Electric Ei-8001 User Manual 2016
Note: at low speed, high torque and continuous operation, a forced cooling special motor must be used
Applications
Rich Electric Ei-8001 User Manual Youtube
Rapid release pro2 user manual rev. ‧ Booster Oil Pumping Station
‧ Punch Press
‧ Tram Line in Mining Operation
‧ Surface Winder
‧ Application requirements; V/Hz (2%), sensorless vector (0.1%), or flux vector control (0.01% with motor-mounted encoder and drive-mounted PG-X2 card required).
‧ Punch Press
‧ Tram Line in Mining Operation
‧ Surface Winder
‧ Application requirements; V/Hz (2%), sensorless vector (0.1%), or flux vector control (0.01% with motor-mounted encoder and drive-mounted PG-X2 card required).